Effect of inlet air relative humidity on heat transfer in air conditioning system

Authors

  • Teerachai Howongsakun Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University
  • Purimpat Sujumnongtokul Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University
  • Somnuk Theerakulpisut Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University
  • Pattayagorn Palasan Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University

Keywords:

heat transfer, relative humidity, air conditioning system

Abstract

To understand the behavior of heat transfer of cooling coil or the evaporator of air conditioning system is very essential. This research is aiming to study on the effect of inlet air relative humidity on the sensible heat transfer rate. The tested coil of the air conditioning system is fined tube type. The experimental rig was set up followed the international ASHRAE standards. The cooling coil was tested under the inlet air conditions with dry-bulb temperature from 27 ̊C to 40 ̊C, relative humidity from 50% to 100%, and frontal air velocity from 1 m/s to 3m/s; in conclusion, it was found that the sensible heat transfer  was decreased when the relative humidity of the inlet air increased. The results show in graphs from can be used to the air-condition design.

References

ASHRAE. (1986). Standard 41.1 method for temperature measurement. Atlanta: American Society of Heating, Refrigerating and AirConditioning Engineers, Inc.

ASHRAE. (1987). Standard 41.2 methods for Laboratory Airflow measurement. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers,Inc.

Fethi Halici and Imdat Taymaz. (2006). Experimental study of the airside performance of tube row spacing in finned tube heat exchangers. Heat Mass Transfer, 42, 817-822.

Fethi Halıcı, I˙mdat Taymaz, and Mehmet Gu¨ndu¨z. (2001). The effect of the number of tube rows on heat, mass and momentum transfer in flat-plate finned tube heat exchangers. Energy, 26, 963-972.

ISO. (2003). standard 5167-2 measurement of fluid flow by means of pressure differential devices inserted in circular-cross section conduits running full-Part 2:Orifice plate. Switzerland: International Organization for Standardization.

Xiaokui Ma, Guoliang Ding, Yuanming Zhang, and Kaijian Wang. (2007). Airside heat transfer and friction characteristics for enhanced finand-tube heat exchanger with hydrophilic coating under wet conditions. International Journal of Refrigeration, 30, 1153-1167.

Xiaokui Ma, Guoliang Ding, Yuanming Zhang, and Kaijian Wang. (2007). Effects of hydrophilic coating on air side heat transfer and friction characteristics of wavy fin and tube heat exchangers under dehumidifying conditions. Energy Conversion and Management, 48, 2525-2532.

Xiaokui Ma, Guoliang Ding, Yuanming Zhang, and Kaijian Wang. (2009). Airside characteristics of heat, mass transfer and pressure drop for heat exchangers of tube-in hydrophilic coating wavy fin under dehumidifying conditions. International Journal of Heat and Mass Transfer, 52, 4358-4370.

Downloads

Published

2025-07-08

How to Cite

Howongsakun, T. ., Sujumnongtokul, P. ., Theerakulpisut, S. ., & Palasan, P. (2025). Effect of inlet air relative humidity on heat transfer in air conditioning system. Journal of Industrial Technology : Suan Sunandha Rajabhat University, 5(1), 24–31. retrieved from https://ph01.tci-thaijo.org/index.php/fit-ssru/article/view/251993

Issue

Section

Research Articles