A Study on the Impact of 2k±1 Harmonic Components on the Lifetime of Oil-Immersed Transformers
Main Article Content
Abstract
This paper investigates the impact of 2k±1 harmonic components on the lifetime reduction of oil-immersed power transformers, aiming to prevent insulation degradation caused by excessive hot-spot temperatures. In the first stage, the top-oil and winding hot-spot temperatures were experimentally measured. The obtained results showed good agreement with the proposed mathematical model. In the second stage, transformer load cycles under overloading conditions were simulated, with the fundamental current ranging from 110% to 150% of the rated current. Ambient temperature data from Kanchanaburi Province, recorded by Meteorological Department Station No. 450201, were employed in the simulation. The results indicate that at 150% overloading, both the top-oil and hot-spot temperatures exceeded the permissible limits, leading to a reduction in transformer lifetime to only 0.72 years. These findings highlight the significant influence of harmonic distortion on transformer thermal aging and provide useful insights for preventing insulation failure and improving long-term power system reliability and planning.
Article Details
References
M. M. Islam, D. Sutanto, and K. Muttaqi, “Protecting PFC capacitors from overvoltage caused by harmonics and system resonance using high temperature superconducting reactors,” IEEE Transactions on Applied Superconductivity, vol. 29, no. 2, pp. 1–5, Mar. 2019.
S. A. Saleh, E. W. Zundel, J. Cardenas, E. F. S. Hill, J. Meng, and G. Y. Morris, “Effects of loading levels on harmonic distortion in power transformers due to GIC flows,” in 2023 IEEE Industry Applications Society Annual Meeting (IAS), 29 Oct.–2 Nov. 2023, pp. 1–6.
R. Tamang, B. Shrestha, A. Kashichhwa, R. Gautam, et al., “Analysis of the effect of current harmonic induced heating on transformer ageing,” in 4th International Conference on Role of Energy on Sustainable Social Development (RESSD), 2025, pp. 1–6.
S. Im, S. Park, J. Kim, J. Chin, K. Cha, and M. Lim, “Temperature prediction of ultra-high-speed SPMSM for FCEV air compressor considering PWM current harmonics,” in 2021 IEEE Vehicle Power and Propulsion Conference (VPPC), 25–28 Oct. 2021, pp. 1–6.
S. Tadsuan, “Testing and Planning of Load of Oil-Immersed Transformer under Non-linear Load Condition in Bangkok and Surrounding Area,” KMUTT Research and Development Journal, vol. 31, no. 2, pp. 335–355, Apr.–Jun. 2008. (in Thai)
P. Sukserm and S. Tadsuan, “Comparison of testing results of oil-immersed transformer under linear load and non-linear load conditions,” SAU Journal of Science & Technology, vol. 4, no. 1, Jan.–Jun. 2018, pp. 1–10. (in Thai)
S. Tadsuan and P. Sukserm, “Testing and prediction of the temperature of oil-immersed transformer under non-linear load condition with 1 phase rectifier,” EAU Heritage Journal of Science and Technology, vol. 12, no. 3, Sep.–Dec. 2018, pp. 1–10. (in Thai)
T. Chegsakul and T. Tayjasanant, “An impact of harmonic currents, load levels and ambient temperatures on transformer loss of life,” in 2019 2nd International Conference on Clean Energy and Electrical Systems, 27–29 Jun. 2019, Nanjing, China, pp. 1–6.
A. Elmoudi, M. Lehtonen, and H. Nordman, “Effect of harmonics on transformers loss of life,” in Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, Toronto, ON, Canada, 2006, pp. 1–6.
ANSI/IEEE C57.91, IEEE Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Distribution Transformers Rated 500 kVA and Less with 65°C or 55°C Average Winding Rise, 1981.
ANSI/IEEE C57.92, IEEE Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Power Transformers, up to and including 100 MVA with 65°C or 55°C Average Winding Rise, 1981.
ANSI/IEEE C57.115, IEEE Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Power Transformers Rated in Excess of 100 MVA 65°C Winding Rise, 1981.
W. P. Linden, “An investigation of the thermal performance of an oil-filled transformer winding,” IEEE Transactions on Power Delivery, vol. 7, no. 3, pp. 1347–1357, Jul. 1992.
IEEE Std C57.110, IEEE Recommended Practice for Establishing Transformer Capability When Supplying Non-sinusoidal Load Currents, 1998.
S. Kulshreshtha and D. K. Chaturvedi, “Effect of generated harmonics on transformer losses due to solar penetration,” International Research Journal on Advanced Engineering and Management, vol. 2, no. 6, pp. 1939–1945, Jun. 2024.
M. H. Mohd Wazir, D. Mat Said, N. M. Sapari, M. S. M. Yunus, and Z. I. M. Yassin, “An electro-thermal modeling of distribution transformer for hottest spot evaluation under photovoltaic-induced harmonics,” International Journal of Renewable Energy Development, vol. 14, no. 3, pp. 450–462, May 2025.
N. Miteva, L. Sima, and K. J. Dagan, “Power loss calculation in oil-type distribution transformers supplying nonlinear loads,” Electronics, vol. 14, 2500, pp. 1–16, 2025.
IEC 354, Loading Guide for Oil-Immersed Power Transformer, 1991.
Thai Meteorological Department, Agroclimatological Data, Kanchanaburi Province, Station 450201, 2019–2024. [Online]. Available: https://www.tmd.go.th/. [Accessed: June. 1, 2025].
Z. Yuan, H. Wu, X. Jiang, and J. Zhao, “Investigating aging characteristics of oil-immersed power transformers’ insulation in electrical–thermal–mechanical combined conditions,” Energies, vol. 16, no. 19, p. 6865, 2023. [Online]. Available: https://pmc.ncbi.nlm.nih.gov/articles/PMC10647747/ [Accessed: Oct. 31, 2025].
G. Kumar, S. Nandini, A. Chandrasekaran, and A. S. Rao, “Comprehensive assessment of transformer oil after thermal aging,” Energies, vol. 18, no. 8, p. 1915, Apr. 2023. [Online]. Available: https://www.mdpi.com/1996-1073/18/8/1915 [Accessed: Oct. 31, 2025].