DETECTION OF PHYTOPHTHORA SPP. IN DURIAN USING LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) METHOD

Authors

  • Dueantem Thongphueak -
  • Jirapat Chanthamalee
  • Sirirat Wachiralurpan
  • Suphitcha Augkarawaritsawong

Keywords:

Phytophthora, Palmivora, Dipstick DNA biosensor, LAMP

Abstract

The research was to study root rot and stem rot of durian disease from Phytophthora palmivora. A total of 20 samples of durian disease symptoms were collected from Khao Khitchakut District and Kaeng Hang Maeo District, Chanthaburi Province, and 12 samples of P. palmivora and 8 samples were not detected. The characterisation of P. palmivora colony morphology was tested by slide culture was found that the isolated had a rosette colony. Light microscopy showed that sporangium was ovoid. When cultured on carrot agar, it grew well. The analysis of P. palmivora by Loop-Mediated Isothermal amplification (LAMP) Method combined with dipstick DNA biosensor was found to detect 12 sample. The sensitivity of LAMP for P. palmivora detection was found that the lowest concentration was 10-5 ug/ml. The detection of specificity primer to showed no cross-reactivity with other fungal. The analytical method are specificity to P. palmivora. The LAMP specific, but it did not detect another fungus. Therefore, the analysis of P. palmivora in durian using LAMP technique with dipstick DNA biosensor was a rapid method. It was used for the analysis of P. palmivora with high accuracy, easy use, without expensive tools, within 60-90 minutes and using very little DNA volume. The diagnosis of infection can be analyzation to rapidly and efficiently this technique can be used to monitor and control the spread of disease.

References

Alvarez, E., Marroquín-Guzmán, M., Mejía, J.F., & Pardo, J.M. (2010). Early detection of Phytophthora palmivora in oil palm, using real-time polymerase chain reaction (QPCR) and molecular beacon probes. APS Caribbean Division, 101, S253-S256.

Dai, T., Wu, X., & Kang, Z. (2015). LAMP (loop-mediated isothermal amplification) detection primer combination for phytophthora palmivora, and LAMP detection kit and LAMP detection method thereof CN 104313176 A. Rui test precision medical testing (Shanghai) Co., Ltd.

Hunter, J., & Kunimoto, R. (1974). Dispersal of Phytophthora palmivora. Phytopathology, 64, 202-206.

Li, Y., Fan, P., Zhou, S., & Zhang, L. (2017). Loop-mediated isothermal amplification (LAMP): A novel rapid detection platform for pathogens. Microbial pathogenesis, 107, 54-61.

Lim, T., & Chan, L. (1986). Fruit rot of durian caused by Phytophthora palmivora. PERTANIKA., 9(3), 269-276.

Lü, P., He, Y., Lin, F., Pan, Y., Yu, Q., Guo, Z., . . . Fu, Y. (2019). Rapid detection of Bombyx mori bidensovirus by loop-mediated isothermal amplification based lateral flow dipstick assay for field applications. Journal of invertebrate pathology, 163, 75-81.

Notomi, T., Mori, Y., Tomita, N., & Kanda, H. (2015). Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects. Journal of microbiology, 53(1), 1-5.

Sangchote, S., Poonpolgul, S., Sdoodee, R., Kanjanamaneesathian, M., Baothong, T., & Lumyong, P. (2004). 4.3 Phytophthora Diseases in Thailand. Diversity and management of Phytophthora in Southeast Asia, 77, 1-102.

Sattabongkot, J., Tsuboi, T., Han, E.-T., Bantuchai, S., & Buates, S. (2014). Loop-mediated isothermal amplification assay for rapid diagnosis of malaria infections in an area of endemicity in Thailand. Journal of clinical microbiology, 52(5), 1471-1477.

Tomita, N., Mori, Y., Kanda, H., & Notomi, T. (2008). Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nature protocols, 3(5), 877-882.

Zasada, A.A., Wiatrzyk, A., Czajka, U., Brodzik, K., Formińska, K., Mosiej, E., . . . Wdowiak, K. (2020). Application of loop-mediated isothermal amplification combined with colorimetric and lateral flow dipstick visualization as the potential point-of-care testing for Corynebacterium diphtheriae. BMC Infectious Diseases, 20(1), 1-9.

Downloads

Published

2022-12-28

How to Cite

Thongphueak, D., Chanthamalee, J. . ., Wachiralurpan, S. . ., & Augkarawaritsawong, S. . . (2022). DETECTION OF PHYTOPHTHORA SPP. IN DURIAN USING LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) METHOD. PSRU Journal of Science and Technology, 7(3), 1–14. Retrieved from https://ph01.tci-thaijo.org/index.php/Scipsru/article/view/249876

Issue

Section

Research Articles