Evaluation of Response Modification Factor for 4-story RC Shophouses

Main Article Content

Eknara Junda

Abstract

This paper presents the evaluation of the response modification factor (R) for 4-story reinforced concrete shop houses in Thailand. The buildings, some of which were designed for earthquakes and some that were not, were used as a case study. For the seismic design, two different types of structural systems, intermediate RC moment resisting frames and special RC moment resisting frames, were considered and designed according to Thailand’s seismic design code, namely DPT-1302. In this study, nonlinear static analysis (pushover analysis) was employed and the analytical results were compared with the DPT-1302 standard. The results indicated that the response modification factors for both the intermediate RC moment resisting frames and the special RC moment resisting frames from the analysis were greater than the factors prescribed by the DPT-1302 standard.

Article Details

Section
Engineering Research Articles

References

[1] Seismic Detailing and Design Requirements for Reinforced Concrete Buildings and Structures, National Standard DPT-1301-50, 2007 (in Thai).

[2] Seismic Resistant Design of Buildings and Structures, National Standard DPT-1302, 2009 (in Thai).

[3] Design of Structures for Earthquake Resistance, Eurocode 8, 2003.

[4] Criteria for earthquake resistant design of structures, BIS IS 1893, 2002.

[5] Minimum Design Loads for Buildings and Other Structures, ASCE/SEI 7-05, 2005.

[6] NEHRP provisions for the seismic rehabilitation of buildings, FEMA 273, 1997.

[7] J. Kim and H. Choi, “Response modification factors of chevron-braced frames,” Engineering Structures, vol. 27, no. 2, pp. 285–300, January 2005.

[8] E. Miranda and V. V. Bertero, “Evaluation of strength reduction factors for earthquakeresistant design,” Earthquake Spectra, vol. 10, no. 2, pp. 357–379, May 1994.

[9] M. H. Arslan and I. H. Erkan “An investigation on overstrength factor of reinforced concrete buildings in Turkish Earthquake Draft Code (TEC-2016),” International Journal of Civil, Environmental, Construction and Architectural Engineering, vol. 10, no. 12, 2016.

[10] M. Mahmoudi and M. Zaree, “Evaluating response modification factors of concentrically braced steel frames,” Journal of Constructional Steel Research, vol. 66, no. 10, pp. 1196–1204, October 2010.

[11] A. Mondal, S. Ghosh, and G. R. Reddy, “Performancebased evaluation of the response reduction factor for ductile RC frames,” Engineering Structures, vol. 56, pp. 1808–1819, November 2013.

[12] A. Ruksa, “Earthquake resistant design of buildings for different intensity level in Thailand” M.S. thesis, Department of Civil Engineering, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, 2012 (In Thai).

[13] Building Code Requirements for Structural Concrete and Commentary, ACI 318-08, 2008.

[14] J. B. Mander, M. J. N. Priestley, and R. Park, “Theoretical stress-strain model for confined concrete,” Journal of Structural Engineering, vol. 114, pp 1804–1826, 1988.

[15] Prestandard and commentary for the seismic rehabilitation of buildings, FEMA-356, 2000.

[16] M. J. N. Priestley, “Displacement-based seismic assessment of reinforced concrete buildings,” Journal of Earthquake Engineering, vol. 1, no. 1, pp. 157–192, 1997.

[17] G. H. Powell, Perform 3D Program, Berkeley. Calif.: Computers & Structures Inc., 2007.

[18] A. Kham, S. Lee, J. Kochanin, and P. Warnitchai, “Energy-based seismic strengthening design of non-ductile reinforced concrete frames using bucking-restrained braces,” Engineering Structures, vol. 81, pp. 110–122, 2014.