THE BURIED PIPE LEAK DETECTION IN CASE OF LEAK OCCUR ON THE BRANCH LINE

Main Article Content

ธเนศ วิลาสมงคลชัย
ทิชากร วิสาลสกล
ฉัตรรัฐฐ์ คุ้มผาติ

Abstract

The leakage of underground pipeline occurred losses and harmful accident, especially the fuel pipeline (eg. oil, natural gas, hydrogen). The pipeline inspection using dynamics pressure has been developed with the advantages on low noise, long range, accessible, and 24/7 online inspection. However, a small leak rate and the leak on the branch line were the limitations of this inspection method which cannot locate the leak point accurately especially on the lacking of dynamic pressure data on the branch line. This research compares the results of cross correlation method and scaling-square method, found that cross correlation method achieves higher accuracy (1.82% error) but cannot indicate the leak point from the branch line. For the leak indication, the frequency analysis of leak signal has been used and the low frequency bandwidth is able to indicate the leak point from branch line.

Article Details

How to Cite
วิลาสมงคลชัย ธ., วิสาลสกล ท., & คุ้มผาติ ฉ. (2019). THE BURIED PIPE LEAK DETECTION IN CASE OF LEAK OCCUR ON THE BRANCH LINE. Journal of Energy and Environment Technology of Graduate School Siam Technology College, 6(1), 54–61. Retrieved from https://ph01.tci-thaijo.org/index.php/JEET/article/view/198179
Section
Research Article

References

[1] Zhang, Y. et. al, (2014). Leak detection monitoring system of long distance oil pipeline based on dynamic pressure transmitter, Measurement, Vol. 49, pp. 382–389.

[2] Jin, H. et. al., (2014). Integrated leakage detection and localization model for gas pipelines based on the acoustic wave method, Journal of Loss Prevention in the Process Industries, Vol. 27, pp. 74-88.

[3] LB defence Group., (2007). Wavealert: Acoustic Leak Detection System for pipeline.

[4] Lin, W. and Zhang, X., (2006). A Novel Approach for Dynamic Pressure Transducer Based Pipeline Leak Detection, Proceedings of the 6th World Congress on Intelligent Control and Automation, Dalian China, 21 – 23 June 2006.

[5] รายงานผลการตรวจสอบ “โครงการวิจัยและออกแบบเครื่องต้นแบบตรวจสอบการรั่วของท่อก๊าซ (ระยะดำเนินการที่ 1)” 5 มกราคม พ.ศ.2558, บริษัท ซีโร่ลอส จำกัด รายงานต่อบริษัท ปตท. (มหาชน) จำกัด

[6] ธเนศ วิลาสมงคลชัย, 2016, การตรวจสอบการรั่วของท่อแก๊สธรรมชาติที่สภาวะการรั่วไหลต่ำโดยใช้อุปกรณ์ตรวจสอบความดันแบบพลวัต, การประชุมทางวิชาการระดับชาติ (TECHCON 2016), วิทยาลัยเทคโนโลยีสยาม

[7] Niloufar Motazedi and Stephen Beck, (2017), Leak detection using cepstrum of cross-correlation of transient pressure wave signals, J Mechanical Engineering Science, pp. 1–13.