Evaluation of Rooftop Solar PV Performance of Different PV Module Technologies operating in Thailand
Keywords:
เซลล์แสงอาทิตย์,, แผงเซลล์แสงอาทิตย์,, สมรรถนะของระบบ,, ระบบผลิตไฟฟ้าจากเซลล์แสงอาทิตย์แบบติดตั้ง บนหลังคาAbstract
This paper presents the evaluation results of the performance ratio (PR) of different photovoltaic (PV) module technologies by installing the six generated PV systems onto roof in Thailand with records data of one year period. It was found that a-Si:H PV system has a highest initial PR of 82.2%, while mono c-Si PV system has a lowest PR of 68.9%. Furthermore, it also found that poly-Si PV module technology is suitability and the best worthiness for use in rooftop solar PV system on present-day.
References
[2] L. Fara and M. Yamaguchi, “Advanced solar cell materials, Technology, modeling and simulation, Hershey”, PA: Engineering Science Reference, 2013.
[3] International Electrotechnical Commision, “Photovoltaic system performance monitoring – Guidelines for measurement, data exchange and analysis IEC61724”, IEC standard, 1998.
[4] pvXchange GmbH [Online], Available : http://www.pvxchange.com, [2014, October].
Downloads
Published
How to Cite
Issue
Section
License
The published articles are copyrighted by the School of Engineering, King Mongkut's Institute of Technology Ladkrabang.
The statements contained in each article in this academic journal are the personal opinions of each author and are not related to King Mongkut's Institute of Technology Ladkrabang and other faculty members in the institute.