Over/Under-Voltage Islanding Detection Technique of Anti-Islanding for Grid-Connected Distributed Generation on Matlab/Simulink

Authors

  • มานพ ยิ่งรัมย์

Keywords:

Islanding Detection,, Distributed Generation,, Grid-Connected

Abstract

This paper presents an over/under-voltage islanding detection technique of anti-islanding for grid-connected distributed generation on Matlab/Simulink. To demonstrate the effectiveness and relevant content for this technology bring to use. The simulation results show that the over/under-voltage islanding detection technique is a high efficiency, can the fast anti-islanding, has not signal injection of perturbation into the power system network, usability dose not difficult. But the technique has a weakness because it has a wide nondetection zone, if active powers to be inside -24.39 % £ DP/P £ 38.41 % when islanding condition occurs, the technique cannot detect islanding condition.

References

[1] M. Yingram, “Passive Islanding Detection Techniques of Anti-Islanding for Grid-Connected Distributed Generation,” Ladkrabang Engineering Journal, Vol.30, No.3, pp.19-24, September, 2556.
[2] IEEE recommended practice for grid interface of photovoltaic (PV) systems, IEEE Std. 929, 2000.
[3] D. Velasco, C.L. Trujillo, G. Garcera and E. Figueres, “Review of anti-islanding techniques in distributed generators,” Renewable and Sustainable Energy Reviews 14, pp.1608–1614, February 2010.
[4] Zhihong Ye, Amol Kolwalkar, Yu Zhang, Pengwei Du and Reigh Walling, “Evaluation of Anti-Islanding Schemes Based on Nondetection Zone Concept,” IEEE Transactions on Power Electronics 19, pp.1171-6, September 2004.
[5] M. Valentini, S. Munk-Nielsen, F. Valderrey Sanchez and U. Martinez De Estibariz, “A New Passive Islanding Detection Method for Grid-Connected PV Inverters,” International Symposium on Power Electronics, 2008.
[6] S. Muangpongoen, “Anti-islanding for Grid-connected Single Phase Inverter,” M.Eng Thesis, Faculty of Engineering, King Mongkut's University of Technology North Bangkok, Thailand, 2554.
[7] M. Yingram, “Passive Islanding Detection Techniques of Anti-Islanding for Grid-Connected Distributed Generation on Matlab/Simulink,” Research Report, Rajabhat Chaiyaphum University, Thailand, September 2557.

Downloads

Published

2020-06-16

How to Cite

[1]
ยิ่งรัมย์ ม., “Over/Under-Voltage Islanding Detection Technique of Anti-Islanding for Grid-Connected Distributed Generation on Matlab/Simulink”, Eng. & Technol. Horiz., vol. 32, no. 1, pp. 67–72, Jun. 2020.

Issue

Section

Research Articles