Bond Strength of Concrete and Round Steel Bar Which Use Chemical Cement
Main Article Content
Abstract
This project was conducted to compare the bond strength of concrete and round steel (fixed in fresh concrete) with bond strength of concrete and round steel bar but used chemical cement.
- Round steel bar used 3 sizes of diameter, 6 mm., 6 mm., 9mm. and 12 mm.
- Chemical cement used 3 types.
- Depth of round steel bar in concrete 5 cm., 20 cm. and 15 cm.
The results showed that bond strength of concrete and round steel bar with chemical cements are more the other without chemical cements.
Article Details
How to Cite
Suwansukroad, N., Pipatchaisiri, K., Suwatanapoonlarb, C., & Tansiri, C. (2013). Bond Strength of Concrete and Round Steel Bar Which Use Chemical Cement. Engineering and Applied Science Research, 23(1), 149–160. Retrieved from https://ph01.tci-thaijo.org/index.php/easr/article/view/8084
Issue
Section
ORIGINAL RESEARCH
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.