Effect of nozzle position on water ejector efficiency

Main Article Content

Sutida Phitakwinai
Sirichai Thepa
Wanich Nilnont

Abstract

The aim of this experimental is to investigate the efficiency water ejector. The effect of nozzle position on its efficiency was investigated. Nozzle position varied the ratio of nozzle-to-throat spacing to throat diameter (X = L/D) with values of 0, 0.5, 1, 2 and 3 respectively. The maximum water ejector efficiency obtains for nozzle-to-throat spacing to throat diameter ratio is approximate 14 %. The experimental results were found in good agreement with the ESDU design guide.

Article Details

How to Cite
Phitakwinai, S., Thepa, S., & Nilnont, W. (2016). Effect of nozzle position on water ejector efficiency. Engineering and Applied Science Research, 43, 196–198. Retrieved from https://ph01.tci-thaijo.org/index.php/easr/article/view/70185
Section
ORIGINAL RESEARCH