A Design of Low Cost 12-Lead ECG Acquisition System Using Raspberry PI
Main Article Content
บทคัดย่อ
This paper presents a new design of low cost 12-lead Electrocardiogram (ECG) acquisition system. The system is an integration of a biosignal analog-to-digital front-end
evaluation board, supplied by Texas InstrumentTM, and a widely known controller from Raspberri PITM. These two separately available gadgets were connected and operated by the costom-made software. This acquisition system is made for long-term multi-channel physiological signals recording with its own storage. With no need of an extra computer for operating, the system is stand-alone working at low cost. For more than two hours, our prototype unit was running through a test, acquiring 12-lead ECG signal from a simulator at 500Hz sampling frequency. The restored signals were constantly confirmed. The target groups of this work are the educators and researchers in biomedical engineering area who are demanding the biopotential signals. Our future work is to develop a new user interface and data analysis software.
Article Details
นโยบายการรับบทความ
กองบรรณาธิการวารสารสถาบันเทคโนโลยีไทย-ญี่ปุ่น มีความยินดีรับบทความจากอาจารย์ประจำ และผู้ทรงคุณวุฒิในสาขาวิศวกรรมศาสตร์และเทคโนโลยี ที่เขียนเป็นภาษาไทยหรือภาษาอังกฤษ ซึ่งผลงานวิชาการที่ส่งมาขอตีพิมพ์ต้องไม่เคยเผยแพร่ในสิ่งพิมพ์อื่นใดมาก่อน และต้องไม่อยู่ในระหว่างการพิจารณาของวารสารอื่นที่นำส่ง ดังนั้นผู้สนใจที่จะร่วมเผยแพร่ผลงานและความรู้ที่ศึกษามาสามารถนำส่งบทความได้ที่กองบรรณาธิการเพื่อเสนอต่อคณะกรรมการกลั่นกรองบทความพิจารณาจัดพิมพ์ในวารสารต่อไป ทั้งนี้บทความที่สามารถเผยแพร่ได้ประกอบด้วยบทความวิจัย ผู้สนใจสามารถศึกษาและจัดเตรียมบทความจากคำแนะนำสำหรับผู้เขียนบทความ
การละเมิดลิขสิทธิ์ถือเป็นความรับผิดชอบของผู้ส่งบทความโดยตรง บทความที่ได้รับการตีพิมพ์ต้องผ่านการพิจารณากลั่นกรองคุณภาพจากผู้ทรงคุณวุฒิและได้รับความเห็นชอบจากกองบรรณาธิการ
ข้อความที่ปรากฏภายในบทความของแต่ละบทความที่ตีพิมพ์ในวารสารวิชาการเล่มนี้ เป็น ความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่าน ไม่เกี่ยวข้องกับสถาบันเทคโนโลยีไทย-ญี่ปุ่น และคณาจารย์ท่านอื่น ๆ ในสถาบัน แต่อย่างใด ความรับผิดชอบด้านเนื้อหาและการตรวจร่างบทความแต่ละบทความเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใด ๆ ผู้เขียนแต่ละท่านจะต้องรับผิดชอบบทความของตนเองแต่ผู้เดียว
กองบรรณาธิการขอสงวนสิทธิ์มิให้นำเนื้อหา ทัศนะ หรือข้อคิดเห็นใด ๆ ของบทความในวารสารสถาบันเทคโนโลยีไทย-ญี่ปุ่น ไปเผยแพร่ก่อนได้รับอนุญาตจากผู้นิพนธ์ อย่างเป็นลายลักษณ์อักษร ผลงานที่ได้รับการตีพิมพ์ถือเป็นลิขสิทธิ์ของวารสารสถาบันเทคโนโลยีไทย-ญี่ปุ่น
ผู้ประสงค์จะส่งบทความเพื่อตีพิมพ์ในวารสารวิชาการ สถาบันเทคโนโลยีไทย-ญี่ปุ่น สามารถส่ง Online ที่ https://www.tci-thaijo.org/index.php/TNIJournal/ โปรดสมัครสมาชิก (Register) โดยกรอกรายละเอียดให้ครบถ้วนหากต้องการสอบถามข้อมูลเพิ่มเติมที่
- กองบรรณาธิการ วารสารสถาบันเทคโนโลยีไทย-ญี่ปุ่น
- ฝ่ายวิจัยและนวัตกรรม สถาบันเทคโนโลยีไทย-ญี่ปุ่น
เลขที่ 1771/1 สถาบันเทคโนโลยีไทย-ญี่ปุ่น ซอยพัฒนาการ 37-39 ถนนพัฒนาการ แขวงสวนหลวง เขตสวนหลวง กรุงเทพมหานคร 10250 ติดต่อกับคุณพิมพ์รต พิพัฒนกุล (02) 763-2752 , คุณจุฑามาศ ประสพสันติ์ (02) 763-2600 Ext. 2402 Fax. (02) 763-2754 หรือ E-mail: JEDT@tni.ac.th
References
“Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology,” Eur. Heart J., vol. 17, no. 3, pp. 354-381, Mar.1996.
A. M. Nasrabadi and M. H. Kani, “Design of ECG acquisition and transmission via Bluetooth with heart disease diagnosis,” in 2011 IEEE International Workshop on Medical Measurements and Applications Proceedings (MeMeA), 2011, pp. 55-58.
C. Sun, J. Liao, G. Wang, B. Li, and M. Q.-H. Meng, “Design of ECG acquisition and transmission via Bluetooth with heart disease diagnosis,” in IEEE International Conference on Information and Automation, 2013, p. 368.
W. Baochun, L. Min, Y. Yaning, and Z. Weiwei, “ECG acquisition circuit design based on C8051F330,” in Proceedings of 2012 IEEEEMBS International Conference on Biomedical and Health Informatics, 2012, pp. 93–96.
Z. Gao, J. Wu, J. Zhou, W. Jiang, and L. Feng, “Design of ECG Signal Acquisition and Processing System,” in Proceedings of the 2012 International Conference on Biomedical Engineering and Biotechnology, Washington, DC, USA, 2012, pp. 762-764.
J. A. G. Gnecchi, A. d J. V. Herrejón, A. d C. T. Anguiano, A. M. Patiño, and D. L. Espinoza, “Advances in the Construction of ECG Wearable Sensor Technology: The ECG-ITM-05 eHealth Data Acquisition System,” in Electronics, Robotics and Automotive Mechanics Conference (CERMA), 2012 IEEE Ninth, 2012, pp. 338-342.
G. D. Gargiulo, P. Bifulco, M. Cesarelli, A. Mcewan, and A. Wabnitz, “Open platform, 32-channel, portable, data-logger with 32 pga control lines for wearable medical device development,” Electronics Letters, vol. 50, no. 16, pp. 1127–1129, Jul. 2014.
A. J. Cook, G. D. Gargiulo, T. Lehmann, and T. J. Hamilton, “Open platform, eight-channel, portable bio-potential and activity data logger for wearable medical device development,” Electronics Letters, vol. 51, no. 21, pp. 1641–1643, 2015.
F. Abtahi, J. Snäll, B. Aslamy, S. Abtahi, F. Seoane, and K. Lindecrantz, “Biosignal PI, an Affordable Open-Source ECG and Respiration Measurement System,” Sensors, vol. 15, no. 1, pp. 93-109, Dec. 2014.
“Low-Power, 8-Channel, 24-Bit Analog Front-End for Biopotential Measurements,” 2015. [Online]. Available: https://www.ti.com.
ADS1298RECG-FE ECG Front-End Performance Demonstration Kit User’s Guide,” 2015. [Online]. Available: https://www.ti.com.
“Altium Limited,” 2015. [Online]. Available: https://www.altium.com.